4 publications found
Yasiru Alahakoon, Lasitha Amarasinghe, Sahan Abeyrathna, Induwara Morawakgoda, Nishani Lucas, Anusha Withana, Pranjeevan Kulasingham, Sampath Perera
Conference
MERCon 2026 Moratuwa Engineering Research Conference (MERCon) , pp. 634-639 · 2026 · Cited by 0
Machine Learning and Pattern RecognitionMedical Image AnalysisPhysiological Monitoring and Digital Health
Abstract
Neonatal jaundice, caused by elevated bilirubin levels, requires timely diagnosis to prevent severe complications. Existing deep learning approaches primarily focus on binary classification of jaundice from visual data, but do not provide quantitative bilirubin estimation. A binary decision alone is insufficient for clinical management, where treatment thresholds depend on precise bilirubin levels. This paper presents a deep-learning-based contactless framework for neonatal jaundice assessment using image-based analysis. The proposed lightweight multi-stage pipeline integrates eye-region obfuscation, skin segmentation, and deep-learning-based image classification and bilirubin estimation. The system first performs jaundice classification; upon positive detection, a regression model is invoked to estimate bilirubin. Furthermore, image-based neonatal screening raises privacy concerns, as facial images of …
Deependra Dewagiri, Kamesh Anuradha, Pabadhi Liyanage, Helitha Kulatunga, Pamuditha Somarathne, Sampath Perera, Nishani Lucas, Anusha Withana, Pranjeevan Kulasingham
Preprint
arXiv arXiv preprint arXiv:2602.23771 · 2026 · Cited by 0
Computer VisionBiosignal ProcessingPhysiological Monitoring and Digital Health
Abstract
Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.
Lohan Atapattu, Sajitha Madugalle, Ms Imasah Nethmal, Erandee Jayathilaka, Avishka Herath, Kithmin Wickremasinghe, Simon L Kappel, Nilan Udayanga, Chamira U. S. Edussooriya
Preprint
arXiv arXiv preprint arXiv:2609.02777 · 2026 · Cited by 0
Biosignal ProcessingMedical Instrumentation and DevicesPhysiological Monitoring and Digital Health
Abstract
Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.
MABCA Bandaranayake, KPU Chandrathilake, JLS Jayasekara, ST Piyasena, ATLK Samrasinghe, Wageesha Manamperi
Preprint
arXiv arXiv preprint arXiv:2608.09784 · 2026 · Cited by 0
Biosignal ProcessingPhysiological Monitoring and Digital Health
Abstract
Meditation has been associated with a range of cognitive and physiological benefits. However, the underlying neural mechanisms of different meditation practices are not yet fully understood. This study investigates whether electroencephalogram (EEG) signals can be used to characterize and distinguish two commonly practiced meditation techniques, namely Samatha and Vipassana, which involve distinct cognitive processes, with Samatha emphasizing sustained concentration and Vipassana emphasizing mindful observation and insight. By extracting features such as band power, coherence and wavelet entropy from EEG signals recorded during pre-meditation resting, Samatha, and Vipassana states, we provide an assessment of how spectral power, signal complexity, and functional connectivity differentiate these practices. Preliminary results from experienced meditators indicate condition-dependent EEG differences, with the most pronounced effects observed in the delta frequency band. These results demonstrate the utility of EEG-based metrics for the objective characterization of meditation and advance our comprehension of the neural processes underlying different contemplative practices.